300 Series Cabinet
$14.43
$24.82
The 300 Series open access monitored cabinet has the ability to constantly monitor the functions of the AED and cabinet. This cabinet provides real-time information concerning incidents and events including email and SMS emergency alerts on the removal or deployment of the AED. Suitable for: Indoor and outdoor use Monitoring: Monitored Sensor monitoring the presence of the AED and the temperature surrounding the defibrillator Http communication between the cabinet and the monitoring server Real-time information concerning incidents or events Immediate and automatic routing of data via Email / SMS Access type: Open access – the 300 Series is an open access monitored cabinet where the AED is freely available to by-standers in the case of an emergency. Compatible with: All leading brand AEDs Dimensions: 388 mm (W) x 423 mm (H) x 201 mm (D) Weight: 3.5 kg Fabrication: Impact-resistant transparent polycarbonate cover and green ABS base Installation: Power supply installation by a licensed electrician 3 x 8 mm wall holes Weatherproof: IP54 Display: Backlit LCD screen displaying the status of the power, network, temperature and presence of the AED. AED status optical sensor: An optical sensor allows for the real time monitoring and presence of the AED in the cabinet. The system ensures the operational status of the AED. Status indicator: Backlit LCD screen displaying the status of the power, network, temperature and presence of the AED Local visual warnings (flashing red LEDs) indicating an access to the cabinet Alarm: Alarmed – Removing the AED from the cabinet will immediately trigger a visual alarm with flashing red LEDs as well as an audible alarm. Day / Night lighting: Automatic day / night lighting – integrated light sensor to light up the AED compartment in dark conditions Flashing white LED in low ambient light conditions to help identify the location of the AED Emergency Cabinet Power supply: 24 Volt DC low voltage power supply. Allows the operation of the communications and ventilation systems. With this specificity as well as its intelligent design, the 300 Series is suitable for outdoor positioning. Backup battery power: Rechargeable back-up battery (approx 4 hours) for essential functions in case of power supply failure. Temperature control system: Temperature control allows the AED unit to be stored and protected in accordance with the AED manufacturer’s specification for safe storage. A thermostatically controlled fan system is activated through a temperature sensor and configured thresholds. The fan system enables heat to be extracted from the cabinet compartment during high temperatures. A visual alarm signals anomalies such as out of range temperatures via flashing red LEDs. Cabinet heating is also available for cold environments. Customisable label: The AED sign is displayed on the front cover and on both sides of the cabinet, an AED / ANZCOR symbol also identifies the cabinet and AED as a vital emergency life saving device. The front label clearly shows the chain of survival in the case of a sudden cardiac arrest and instructions on how to access the AED with the 4 digit code. The front label can be customised to provide additional information for a greater visual impact and compliance with customer requirements. Maintenance access: RFID badge reader (electronic swipe card) allows access for maintenance purposes.
Cabinets & Shrouds